generated from rmcguire/go-server-with-otel
142 lines
8.8 KiB
Markdown
142 lines
8.8 KiB
Markdown
# AGENTS.md — econet-exporter
|
|
|
|
Exporter for Rheem EcoNet / Rheemcloud water heaters, built on the
|
|
`go-app` framework (see the framework's own AGENTS.md for lifecycle details).
|
|
|
|
## Architecture
|
|
|
|
- `main.go` — go-app bootstrap. The **only** app-specific lines are the
|
|
`appServices` slice (registers `&econet.EconetService{}`) and the
|
|
`serviceConfig.LoadEnv()` call (see Config gotcha below).
|
|
- `pkg/econet/econet.go` — `EconetService` implements `service.AppService`.
|
|
It **owns the single `econetclient.Client`** and shares it with the gRPC,
|
|
MCP, and metrics sub-servers. `Init` fails fast if creds are missing, then
|
|
refreshes device state on a ticker **in a background goroutine** (`pollLoop`,
|
|
interval `pollInterval`) so a slow or unreachable cloud never blocks
|
|
HTTP/gRPC server startup. The client is stateless REST, so `ShutdownFunc` is
|
|
effectively a no-op (the poll goroutine stops on ctx cancel).
|
|
- `pkg/econet/econetclient/` — a minimal EcoNet REST client (ClearBlade
|
|
backend). `client.go` does the read REST calls (auth → `getUserDataForApp` →
|
|
`dynamicAction` usage) and caches a snapshot under an `RWMutex`; `device.go`
|
|
decodes the `@...` datapoints into a flat `Device` struct (ported from
|
|
kevinburke/rheemcloud-go, minus MQTT). `Devices()` is empty until the first
|
|
`Refresh` succeeds — consumers just see an empty list (no nil-guarding).
|
|
**No MQTT**, so `WiFiSignal` and `Running`/`RunningState` stay zero.
|
|
- **Writes (SetMode)**: `Client.SetMode` changes a unit's operating mode by
|
|
publishing a desired-state message over ClearBlade's REST publish endpoint
|
|
(`POST /message/{systemKey}/publish`, topic `user/{account_id}/device/desired`,
|
|
payload `{transactionId, device_name, serial_number, "@MODE": <idx>}`). This
|
|
is the HTTP equivalent of the app's MQTT publish — **no MQTT client needed**.
|
|
`@MODE` is an *index* into the device's reported mode list, so `device.go`
|
|
retains that list (`modeEnumText`) and maps a slug → index (`modeIndex`);
|
|
supported modes are device-specific (`Device.SupportedModes`). The change is
|
|
**applied asynchronously** — the new mode only shows up on a later `Refresh`,
|
|
and a 200 from publish means "accepted", not "applied".
|
|
- `pkg/econet/econetgrpc/` — `EconetService` gRPC impl (`ListDevices`,
|
|
`GetDevice`, `SetMode`) + `deviceToProto`. Does **not** own a client; it's
|
|
injected. `SetMode` maps the proto `Mode` enum → client slug; note MCP calls
|
|
it in-process and so **bypass the protovalidate interceptor** (the gRPC/REST
|
|
paths don't), hence `SetMode` re-checks the enum itself.
|
|
- `pkg/econet/econetmcpgen/` — **active** MCP server at `/api/mcp`. Registers
|
|
the tools generated by protoc-gen-go-mcp (`api/econet/v1alpha1/v1alpha1mcp/`)
|
|
against our go-sdk `*mcp.Server` via the `runtime/gosdk` adapter, forwarding
|
|
in-process to the gRPC server. Exposes the same package API as `econetmcp`.
|
|
- `pkg/econet/econetmcp/` — the older hand-written MCP server; a single
|
|
`list_water_heaters` tool delegating to the gRPC server. Kept in place as a
|
|
fallback. **Switch between the two** with the aliased `econetmcp` import in
|
|
`pkg/econet/econet.go` (one line — both packages export identical symbols).
|
|
- `pkg/econet/econetui/` — admin UI served at **`/`** (the root; the HTTP
|
|
server is not "under `/api`" — only the grpc-gateway is, via
|
|
`grpcGatewayPath`). Gated by `enableWebUI` (default true). Server-rendered
|
|
`html/template` + embedded assets (`embed.FS`: Pico.css classless, HTMX,
|
|
per-`generic_type` SVG icons) with a dark-mode toggle (persisted in
|
|
`localStorage`). Reads devices and writes mode through the in-process gRPC
|
|
server, same as the MCP packages. Routes: `GET /` (page), `GET /ui/devices`
|
|
(HTMX poll partial, every 30s), `POST /ui/devices/{serial}/mode` (returns a
|
|
re-rendered card), `GET /ui/devices/{serial}/debug` (raw device JSON for the
|
|
🐛 modal), `GET /static/`. A **fill-level meter** visualizes hot-water
|
|
availability. `iconFor` matches `@TYPE` loosely (substring, case/spacing
|
|
insensitive) since real values vary (e.g. `heatpumpWaterHeaterGen5`).
|
|
Template funcs (`fillClass`/`fillWidth`) take **int32** to match proto fields
|
|
— `html/template` is strict about arg types.
|
|
**Pending state** for a mode change is best-effort: `pending.go` holds a
|
|
TTL-bounded (`pendingTTL`, 90s) desired-mode hint, shown as an "Updating…"
|
|
badge and cleared once the reported mode converges; a full page load ignores
|
|
it (fresh reported state), the poll honors it. **Auth is left to the edge**
|
|
(oauth2-proxy) — the UI/write live at `/` and `/ui/`; keep `/health` and
|
|
`/metrics` on skip-auth so probes/Prometheus keep working.
|
|
- `pkg/econet/econetmetrics/` — OTEL observable gauges (read the client
|
|
snapshot at scrape time; no poller of its own).
|
|
|
|
## Config gotcha (important)
|
|
|
|
go-app's `MustLoadConfigInto` applies env vars **only to the embedded
|
|
`AppConfig`**, not to custom `ServiceConfig` fields. So custom fields need an
|
|
explicit env pass: `ServiceConfig.LoadEnv()` (in `pkg/config/custom.go`) runs
|
|
`env.Parse` over the custom fields (it nils out the embedded `AppConfig` first
|
|
to preserve go-app's own precedence). `main.go` calls it right after
|
|
`MustLoadConfigInto`. If you add a custom config field with an `env:` tag,
|
|
that's all it takes — no extra wiring.
|
|
|
|
- `costPerKWH` is **US dollars per kWh** (0.18 = 18¢), feeding
|
|
`econet_energy_cost_dollars`.
|
|
- **The `default:` tag is NOT applied at runtime for custom `ServiceConfig`
|
|
fields** — `LoadEnv` uses plain `env.Parse` (no `DefaultValueTagName`), so
|
|
`default:` only feeds the JSON schema. A bool that must default to true
|
|
therefore can't be a plain `bool` (zero value = false); `enableWebUI` is a
|
|
`*bool` where nil ⇒ enabled (read via `WebUIEnabled()`). `disableWaterUsage`
|
|
is a plain `bool` because its desired default (poll water usage) is the zero
|
|
value — set it true to skip the wasted water-usage REST call on units that
|
|
don't report it.
|
|
- `econetTLSInsecure` (env `ECONET_TLS_INSECURE`) skips TLS certificate
|
|
verification when connecting to the EcoNet cloud API. It exists because the
|
|
upstream host (cloudblade) serves a
|
|
DigiCert Global Root G1 chain, which is no longer trusted by default in
|
|
current root stores. **Evaluate removing this later** — prefer fixing the
|
|
trust chain (e.g. bundling the needed intermediate/root CA) over disabling
|
|
verification outright.
|
|
|
|
## Metrics conventions
|
|
|
|
- Live state and usage are both read at scrape time inside `RegisterCallback`s
|
|
over `client.Devices()` (cheap, in-memory). The `pollLoop` in `econet.go`
|
|
keeps the snapshot fresh over REST (`client.Refresh`), which folds daily
|
|
energy/water usage totals into each `Device`. No usage cache or event
|
|
draining — the callbacks just read the current snapshot.
|
|
- **Attributes**: dotted/namespaced `econet.*` (semantic-convention style),
|
|
low-cardinality only (serial, device_id, friendly_name, type, generic_type,
|
|
mode, energy_type). **Never** put changing values (timestamps) in attributes
|
|
— `econet_last_updated_seconds` is a metric *value*, and it's suppressed
|
|
until the first refresh so it never emits a garbage epoch.
|
|
- **Units live in metric names** (`_fahrenheit`, `_kwh`, `_gallons`,
|
|
`_dollars`), NOT via `metric.WithUnit` — the OTEL→Prometheus exporter would
|
|
otherwise append a second unit suffix (`..._fahrenheit_F`).
|
|
|
|
## Workflow
|
|
|
|
- Regenerate proto: `make proto` (buf; `PROTO_DIRS=proto/econet/v1alpha1/*`).
|
|
This also runs the `protoc-gen-go-mcp` plugin (see `buf.gen.yaml`), emitting
|
|
the MCP registrars under `api/econet/v1alpha1/v1alpha1mcp/`.
|
|
- Regenerate config schema after config changes: `make schema`.
|
|
- Build/test: `go build ./... && go test ./...`.
|
|
- `econetclient.Device` is a plain struct, so `deviceToProto` and the datapoint
|
|
decoders (`mode`, `enabled`, `setpoint`, `hotWater`) are unit-testable by
|
|
hand-building a `Device` or feeding raw JSON to `newDevice`.
|
|
|
|
## Live verification (needs a real Rheem account)
|
|
|
|
Creds are configured via `ECONET_EMAIL` / `ECONET_PASSWORD`. Run
|
|
`go run . -config config.yaml`, then check: `/metrics` (grep `econet_`),
|
|
`/api/v1alpha1/devices` (REST), grpcurl on `:8081`, and MCP at `/api/mcp`
|
|
(streamable HTTP; POST to `/api/mcp/` with trailing slash — bare `/api/mcp`
|
|
307-redirects). The REST gateway needs `grpcGatewayPathStrip: true` in
|
|
config.yaml (otherwise the `/api` prefix isn't stripped and routes 404).
|
|
|
|
`SetMode` (write) can be driven three ways once a real device is loaded:
|
|
`grpcurl -plaintext -d '{"serial_number":"<sn>","mode":"MODE_HEAT_PUMP"}' :8081 econet.v1alpha1.EconetService/SetMode`,
|
|
`POST /api/v1alpha1/devices/<sn>/mode` with `{"mode":"MODE_HEAT_PUMP"}`, or the
|
|
MCP `econet_v1alpha1_EconetService_SetMode` tool. **Unverified against a live
|
|
account**: whether the user token is authorized to publish over REST (same
|
|
authority as MQTT, but Rheem's topic ACL is untested) — this is the one thing
|
|
that can't be confirmed without a real unit.
|